The smallest SIL3 absolute rotary encoder (Cat 3) currently available comes from TR Electronic.
At just 36 mm in diameter and completely safe, the CD_362+FS from TR Electronic is currently the smallest safe absolute encoder on the market that meets the stringent requirements of SIL3 or PLe with Category 3. In a 36 mm diameter, TR Electronic delivers a redundant encoder system that incorporates two multi-turn gearboxes and probes. Even in this small encoder, TR’s renowned safe bus protocols can be implemented.
Secure bus protocols without overhead:
The safe rotary encoders of the 362 series implement the safe bus protocol in accordance with standards and are certified for CANopen Safety and IO Link Safety.
In contrast, protocols typically transmitted via Industrial Ethernet operate differently: The safe bus protocols PROFIsafe, CIP Safety™, openSAFETY, and FSoE are generated directly and securely within the sensor. They are then transported via an RS485-based serial interface. Here, the “black channel” principle is adhered to: Reliable fault detection is guaranteed regardless of the transmission channel.
The serial interface is deliberately kept simple. Few wires, robust transmission, unshielded cables and direct 5V power supply are optimally suited for use with local controllers.
In contrast, standardized connection technology would take up unnecessary installation space (M12 connectors, bus topology, 24V supply via separate lines).
The use cases of autonomous logistics vehicles (AGVs) present particular challenges for integrated sensors. Multiple steering angles must be detected. The entire steering function must meet safety requirements up to SIL 3, while installation space is extremely limited. Since the units are typically powered by rechargeable batteries, energy efficiency is crucial.
The modular cabling of conventional (even secure) fieldbuses offers no advantage in these highly integrated logistics devices. The control platforms are perfectly capable of controlling sensors and actuators via serial interfaces in a direct point-to-point connection. Certified protocols, which are also transmitted via this physical interface, ensure the security of the transmission: The tested standards, such as those from PROFIsafe, are fully implemented, simply transmitted via a different channel.
This allows users to rely on established and proven transmission protocols without having to use unnecessary components like the cabling.
Medical devices and equipment are becoming increasingly compact. At the same time, they are subject to stringent safety requirements, which is why only type-tested sensors with SIL (Safety Integrity Level) ratings are typically used. The compact design of TR Electronic’s CD_362+FS series is particularly advantageous for these devices. If a standard interface for higher-level communication is required, the CIB2X+FS converter module can convert the serial signals from up to four CD_362+FS encoders into a standard Ethernet interface. This converter module also adheres to the “Black Channel” principle, ensuring reliable error response regardless of the transmission path.
With the CD_362+FS, TR Electronic is once again setting standards in the market for safe absolute encoders. This technology-leading market position, combined with over 40 years of experience in absolute encoders and over 20 years with SIL3-compliant sensors, is an optimal combination for our customers.
The CD_362+FS family summarized:
Mechanics:
- Rotary encoder diameter 36 mm
- Typical installation length 42 mm
- Available as solid shaft and blind hole shaft / plug-in hollow shaft
- Hollow shaft, plug-in hollow shaft: Positive locking with keyway in the clamping ring, shaft diameters 6, 8, 10, 12, 15 mm
- Solid shaft: Friction fit, optionally positive fit with key on surface. Shaft diameters 6, 8, 10 mm
Interfaces:
- CANopen Safety
- IO Link Safety
- SSI+SSI
- SSI+Incremental
via M12 connectors or cable glands
Secure interface protocol, standardized and tested over a serial connection:
- PROFIsafe
- CIP Safety™
- OpenSAFETY
- FSoE
This can be directly read into a control system by the customer.
Safety-oriented design
- Dual-channel scanning within one revolution
- Sampling of revolutions via two gearboxes and separate scanning
- Monitored power supply
- Internal hardware diagnostics and their aggregation into a secure transmission protocol